Rating Range30 - 3000 A

Transfer TypeOpen Transition (CG), Delayed Transition (CGD)

Switch TypeContactor

Product nodes30, 60, 100, 125, 160, 200, 260, 400, 600, 800, 1000, 1200, 1600, 2000, 2600, 3000A

Rated Voltage and Frequency200-480VAC, 50/60 Hz

Phase systemSingle and Three (three phase only >600A)

Number of poles2, 3 and 4 (3 & 4 pole only >600A)

Neutral configurationOptional Solid or Switched neutral

Product typeOpen transition (I-II), Delayed Transition (I-O-II)

Estándar

LCD + keys

Voltage and frequency settings: Pick up and Drop out

Time Delay Settings: Override momentary, Transfer, Generator stop, Center-OFF, Pre-transfer, Post-transfer, Elevator Pre-signal, Elevator Post-signal, and Load shead

Source failure detections: No Voltage, Under/Over Voltage, Phase missing, Voltage unbalance, Invalid frequency, and Incorrect phase sequence

Estándar

LED indications for ATS, S1 and S2 status

Open transition - Standard digital inputs/outputs (1/1)

Delayed transition - Standard digital inputs/outputs (2/1)

Programmable digital inputs/outputs

Auto config (voltage, frequency, phase system)

Source priority (Source 1/2, No priority)

Manual re-transfer

In-phase monitor (synchro check)

Genset exercising: on-load, off-load

Load shedding

Real time clock

Event log

Opcional

Auxiliary contacts for position indication

Additional digital input/output contacts (adding up to 6 each)

12-24 VDC aux supply module for controller

Communication modules

Opcional

Modbus RTU (RS-485)

Modbus/TCP

Profibus DP

ProfiNet Yes

DeviceNet

Ethernet IP

Coming Soon

CONTACTO

SOLICITAR PRESUPUESTO

Rellene este formulario para obtener un presupuesto sobre el equipo que le interesa.

    *Si desea dejar de recibir comunicaciones en el futuro, puede darse de baja enviando un mensaje de texto a STOP, QUIT, END, REVOKE, OPT-OUT, CANCEL, o UNSUBSCRIBE. Pueden aplicarse tarifas de mensajes y datos en función del plan de su operador de telefonía móvil. Al optar por recibir comunicaciones SMS de Blanchard Machinery, acepta recibir mensajes de texto recurrentes sobre actualizaciones de cuenta, notificaciones de pedidos, notificaciones de entrega y asistencia general.

    Este sitio está protegido por reCAPTCHA y se aplican la Política de privacidad y las Condiciones del servicio de Google.

    Lo que obtiene: Una llamada telefónica de un representante o agente. Una estimación del coste de su máquina o del proyecto. Una consulta en persona si es necesario.