it's catit's single

3512C Generator Set

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Request a Quote

Standby Rating1500 ekW

Prime Power Rating1360 ekW

Emissions/Fuel StrategyU.S. EPA Certified

Voltage380 to 13800 Volts

Frequency60 Hz

Speed1800 rpm

Duty CycleStandby, Mission Critical, Prime, Continuous

Maximum Rating1500 ekW

Minimum Rating1230 ekW

Engine Model3512C ATAAC, V-12, 4-Stroke Water-Cooled Diesel

Bore6.69in

Stroke7.48in

Displacement3161.03in³

Compression Ratio14.7:1

AspirationTA

Fuel SystemElectronic unit injection

Governor TypeADEM™ A3

Length - Maximum248.6in

Width - Maximum89.8in

Height - Maximum110in

Dry Weight - Genset (maximum)30790lb

Standard

Air cleaner; single element canister type with service indicator

Optional

Heavy duty air cleaner

Single element filter

Standard

Air cleaner

Standard

Package mounted radiator

Standard

Exhaust flange outlet

Optional

Exhaust mufflers

Standard

Secondary fuel filters

Primary fuel filter with integral water separator

Fuel priming pump

Standard

Matched to the performance and output characteristics of Cat engines

IP23 Protection

Optional

Permanent magnet excitation (PMG)

Oversize and premium generators

Internal excitation (IE)

Anti-condensation heater

Standard

Busbar

Optional

Circuit breakers, IEC compliant

Circuit breakers, UL listed

Standard

Cat ECS Genset controller

Standard

Alarm acknowledge

Over/under frequency (81 o/u)

Reverse power (kW) (32)

Coolant temperature

kVAr (per phase, average & percent)

Overcurrent (50 / 51)

High coolant temperature

Environmental sealed front face

Reverse reactive power (kVAr) (32RV)

kVA (per phase, average & percent)

Volts (L-L & L-N)

Generator set packages include Caterpillar's voltage regulator (IVR). IVR includes reactive droop capability, 3-phase voltage sensing, KVAR / PF modes, RFI suppression, min/max exciter. Limiter and exciter diode monitor

kW-hr (total)

kW (per phase, average & percent)

Low oil pressure

Cat ECS 100

Digital indication for:

Engine cool-down timer

Generator mounted - rear facing

DC volts

1 programmable relay outputs (Form C)

Overspeed

kVAr-hr (total)

1 programmable digital outputs

Communications

Power factor (per phase & average)

Oil pressure (psi, kPa or bar)

True RMS AC metering, 3-phase, +/-2% accuracy

Cat connect

Customizable screens

Low coolant temperature

Over/under voltage (27 / 59)

4 programmable relay outputs (Form A)

Accessory module data link

Warning/shutdown with common LED indication of shutdowns for:

Failure to start (overcrank)

Amps (per phase & average)

Auto/start/stop control

Controls:

Engine cycle crank

Customer data link (Modbus RTU)

Programmable protective relaying functions:

Text alarm/event descriptions

Emergency stop

Speed adjust

Number of I/O varies on options selected

Lamp test

RPM

24 Volt DC operation

Emergency stop pushbutton

Low coolant level

Frequency (Hz)

Generator phase sequence

Load histogram feature

PLC functionality

Standard

Coolant level sensors (Not included with packages without radiator)

SCAC

Radiator fan and fan drive

Coolant drain line with valve

Fan and belt guards

Caterpillar extended life coolant (Not included with packages without radiator, installed SF44CTS

Optional

Coolant

Standard installed ATAAC radiators

Optional installed ATAAC radiators

Optional installed radiators

Water level switch gauges

Standard installed radiators

Standard

Flanged faced outlet(s)

Dry exhaust manifold

Optional

Flanges

Flange and exhaust expanders

Y Adapters

Flexible fittings

Elbows

Mufflers

Standard

Fuel cooler; not included with packages without radiator

Secondary fuel filters

Flexible fuel lines - shipped loose

Fuel priming pump

Optional

Primary fuel filter

Standard

Medium voltage:

Internal excitation (IE)

High voltage

Permanent magnet excitation (PMG)

Winding temperature detectors

NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby)

Busbar connections, right side extension box, bottom cable entry

Busbar connections, top center mounted, top cable entry

Low voltage:

Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)

NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby)

NEMA standard hole pattern

3 phase brushless, Salient pole

NEMA standard hole pattern

6 Leads

Random wound

NEMA standard hole pattern

Form wound

Optional

Differential current transformers (DCT) 15 kV class

RW, IE, 6 Leads, Pitch 0.6667

Differential current transformers (DCT) 8.7 kV class

1400, 1600, 2700 Frames

Space heater

Generator air cleaner

Generator conversion from IE to PM

Low voltage: 380,440 / 480 Volts, 3 Phase, 1800 rpm

Standard

ADEM III

Standard

Parts book

Standard

Gear type lube oil pump

Oil filter, filler and dipstick

Fumes disposal

Lubricating oil

Oil drain lines and valve

Integral lube Oil cooler

Optional

Prelube pumps

Oil level regulator

Oil drains

Lubrication oil in standard sump

Standard

Rubber anti-vibration mounts - shipped loose

Optional

Puck style low efficiency isolators

IBC vibration isolators

Spring type vibration isolators

Standard

45 Amp Charging alternator

Battery and battery rack w/cables

Battery disconnect switch

24 Volt electric starting motor

Optional

10 Amp Battery charger

24 Volt battery set - Dry

Engine barring device

35 Amp Battery charger

Air starting motor

Air pressure regulator

Batteries, racks and cables:

Jacket water heaters

Electric starting motors

Starter cover

Standard

Flywheel and Flywheel housing-SAE No. 00

SAE standard rotation

Right hand servicing

Paint - Caterpillar yellow with high gloss black rails & radiator

Optional

US aid emblem

Optional

EMCP 4.4

Optional

IBC isolators

Rubber anti-vibration mounts

Spring type vibration isolators

Optional

Jacket water heater

Air starting motor with control and silencer

Battery chargers

Charging alternator

Heavy duty starting system

Oversize batteries

Optional

Wiring GP W/O cyl sensors

Pyrometer and thermocouples

Optional

No explosion relief valves

No crankcase explosion relief valves

Explosion relief valves

Crankcase ventilation system

Optional

Cable entry - right side

Center post buss bar

Rear power connections

Right side power connections

2000, 2500, 3200 Amp, 3 Pole, IEC rated Circuit breakers

1600 ,2000, 2500, 3000, 4000 Amp, 3 Pole, UL-100% rated Circuit breakers

Left side power connections

Six lead, six terminal option

2000, 2500 Amp, 4 Pole, IEC rated Circuit breakers

Neutral ground connections

Grounding groups

Optional

Standard engine test charge

PGS Test report @ 1.0 power factor

CSA Certification

IBC seismic Certification

Fuel consumption test

Torsional vibration analysis

Generator test report

Generator fuel consumption test

PGS Test report @ 0.8 power factor

CONTACT US

REQUEST A QUOTE

Complete this form to get a quote on the equipment you are interested in.

    This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

    What You Get: A phone call from a rep or agent. A cost estimate for your machine or the project. An in-person consultation if necessary.