it's catit's single

3516B Generator Set – 2250 kVA Standby Rating

3516B Generator Set – 2250 kVA Standby Rating

The 3516B generator set has been developed for a wide range of applications, from emergency standby installations such as healthcare and datacenters to continuously powering remote installations. The packages can be optimized for performance that matters to you with either low emissions or low fuel consumption versions available. Backed by the worldwide network of Cat dealers ready to support your operation with technical support, service, parts, and warranty, Cat generator sets will provide the reliability and durability you expect.

Request a Quote

Standby Rating2250 kVA

Prime Power Rating2000 kVA

Emissions/Fuel StrategyLow fuel, Low Emissions

Voltage380 to 11000 Volts

Frequency50 Hz

Speed1500 rpm

Duty CycleStandby, Mission Critical, Prime, Continuous

Maximum Rating2250 kVA

Minimum Rating1750 kVA

Engine Model3516B TA, V-16, 4-Stroke Water-Cooled Diesel

Bore6.69in

Stroke7.48in

Displacement4210.64in

Compression Ratio14.0:1 Std

AspirationTA

Fuel SystemElectronic unit injection

Governor TypeAdem™3

Length - Maximum234.5in

Width - Maximum90in

Height - Maximum98.2in

Dry Weight - Genset (maximum)34460lb

Standard

Air Cleaner; single element canister type

Optional

Dual element air cleaner

Single element filter

Standard

Auto / start / stop control

Engine cool-down timer

Environmental sealed front face

Emergency stop pushbutton

Text alarm / event descriptions

24 Volt DC operation

Controls:

Generator mounted - Rear facing

IVR includes reactive droop capability, 3-phase voltage sensing, KVAR / PF modes, RFI suppression, min / max exciter.

Limiter and exciter diode monitor

Generator set packages include Caterpillar' s Voltage Regulator.

EMCP 4.2B

Speed adjust

Alarm acknowledge

Engine cycle crank

Load histogram feature

Lamp test

Digital indication for:

Customizable screens -0 True RMS AC metering, 3-phase, +/-2% accuracy

RPM

PLC functionality

Operating hours

Oil pressure (psi, kPa or bar)

Coolant temperature

DC volts

Power Factor (per phase & average)

Volts (L-L & L-N)

kW (per phase, average & percent)

Amps (per phase & average)

Frequency (Hz)

kVA (per phase, average & percent)

kVAr (per phase, average & percent

Low oil pressure - High coolant temperature

kVAr-hr (total)

High coolant temperature

Warning/shutdown with common LED indication of shutdowns for:

kW-hr (total)

Overspeed

Low coolant temperature

Failure to start (overcrank)

Emergency stop

Over/Under voltage (27 / 59)

Generator phase sequence

Low coolant level

Programmable protective relaying functions:

6 Customer programmable digital inputs

Over/Under Frequency (81 o/u)

Reverse Reactive Power (kVAr) (32RV)

Serial annunciator module data link

Reverse Power (kW) (32)

Number of I/O varies on options selected:

Overcurrent (50 / 51)

Cat Connect

4 Programmable relay outputs (Form A)

Communications:

Customer data link (Modbus RTU)

1 Programmable digital outputs

1 Programmable relay outputs (Form C)

Accessory module data link

3 Analog inputs

Standard

Certified standard PGS provided

ATAAC - 3516E Package Radiators shipped installed

Optional

Standard ambient radiators

Coolant

Optional installed radiators

Optional installed ATAAC radiators

Water level switch gauges

Standard ambient ATAAC radiators

Standard

Dry exhaust manifold

Flanged faced outlet(s)

Optional

Y-Adapters

Flanges

Tier 4 clean emission MOD Kits

Clean emission parts

Flange and exhaust expanders

Flexible fittings

Exhaust offset

Mufflers

Tier 4 dosing cabinet

Tier 4 clean emissions module

Elbows

Standard

Fuel cooler; not included with packages without radiator

Secondary fuel filters

Fuel priming pump

Flexible fuel lines - shipped loose

Optional

Fuel Priming Pumps (Tier 4) - Manual or electric

Primary Fuel Filter

Standard

Right hand servicing

SAE Standard rotation

Flywheel and flywheel housing - SAE No. 00

Caterpillar yellow with high gloss black rails and radiator

Optional

Special paint (Colors other than Caterpillar yellow or high performance paints)

US aid emblem

Standard

Busbar connections, right side extension box, bottom cable entry

High Voltage:

NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime / 150C standby)

Form wound

Internal excitation

NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime / 150C standby)

3 Phase brushless, salient pole

Medium Voltage:

NEMA standard hole pattern

Permanent magnet

Permanent magnet

Winding temperature detectors

Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)

Winding temperature detectors

Low voltage:

Form wound

6 Leads
 

Random wound

Anti Condensation Space Heater

Winding temperature detectors

Busbar connections, top center mounted, top cable entry

NEMA standard hole pattern

Standard

ADEM A3

Standard

English

Standard

Integral lube oil cool

Lubricating oil

Oil filter, filler and dipstick

Gear type lube oil pump

Oil drain lines and valve

Fumes disposal

Optional

Oil level regulator

Prelube pumps

Lube oil in standard sump

Standard

Rails - engine / generator / radiator mounting

Rubber anti-vibration mounts (shipped loose)

Anti-vibration mounts (shipped loose)

Optional

Puck style low efficiency isolators

IBC vibration isolators

Spring type vibration isolators

Standard

24 Volt electric starting motor

45 Amp charging alternator

Battery disconnect switch

Battery and battery rack w/cables

Optional

EMCP 4.3, EMCP 4.4

Controller: [ ] EMCP 4.2 [ ] EMCP 4.3 [ ] EMCP 4.4

Local annunciator module: [ ] NFPA 110 [ ] Custom

Optional

Air Cleaner: [ ] Single element air cleaners [ ] Dual element air cleaners [ ] Heavy duty air cleaners

Battery Charger: [ ] 10A [ ] 20A [ ] 35A

Starting Aids: [ ] 220V 50 Hz Jacket Water Heater

Muffler: [ ] Industrial Grade

Starting Motors: [ ] Standard [ ] Heavy Duty

Batteries: [ ] Standard (1400 CCA) [ ] Heavy Duty (2800 CCA)

Optional

Ventilation system

No explosion relief valves

Explosion relief valves

Optional

Temperature Rise (over 40°C ambient): [ ] 150°C [ ] 125°C [ ] 105°C [ ] 80°C

Optional

Power Termination: [ ] Bus Bar [ ] Circuit Breaker

Circuit breaker trip unit: [ ] LSI [ ] LSIG [ ] LSIG-P

Circuit Breaker rating: [ ] 2000A [ ] 2500A [ ] 3200A [ ] 4000A

Optional

Extended Service Contract (ESC): [ ] 2 Year [ ] 3 Year [ ] 5 Year

Optional

Generator conversion

Space heater

Alternator air cleaner

Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame

Differential current transformers (DCT)

Differntial current transformers (DCT) 8.7 kV and 15 kV classes

Thermostate for space heater

Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, PM, No. of Leads = 6, Pitch = .6667: 1600 and 1800 Frames

Optional

Pyrometer and thermocouples

Optional

Neutral ground connections

Center post busbar

Right side power connections

Left side power connections

2700 Frame, four lead, four terminal

Ground cables between generator and terminal box

Low voltage circuit breakers

Rear power connections

Optional

Torsional vibration analysis reports

Generator set fuel consumption test

PGS test report @ 1.0 power factor

Fuel consumption test

Standard engine test charge

IBC certification

OSHPD certification

Canadian Standards Association certification

PGS test report @ 0.8 power factor

generator test report

Optional

10, 20, 35 and 50 amp battery chargers

Air starting motors

Air pressure regulator

Electric starting motors

Starter cover

Jacket water heaters

Engine barring device

24 Volt battery set - Dry

Optional

Platinum, Gold and Silver coverage

CONTACT US

REQUEST A QUOTE

Complete this form to get a quote on the equipment you are interested in.

    This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

    What You Get: A phone call from a rep or agent. A cost estimate for your machine or the project. An in-person consultation if necessary.