ATC-300+ CONTROLLER

The ATC-300+ is a comprehensive and multifunctional microprocessor-based ATS controller. It is a compact and self-contained panel-mounted device that is designed to replace traditional relay and solid-state logic panels. The ATC-300+ Controller provides programmed flexibility to address the needs of any system. It operates from all system voltages between 120 to 600V, single-phase and three-phase at 50 or 60 Hz. In addition, a period of no control power is provided. The controller monitors the condition of the three-phase line-to-line voltage and frequency of Source 1 and Source 2 power sources and can be programmed for single-phase operation. The ATC-300+ Controller provides the intelligence to ensure that the ATS operates properly through a series of programmed sensing and timing functions.

Request a Quote

Rating Range120 to 600V, single phase and three phase @ 50/60 Hz

Transfer TypeSwitch application dependent

Switch TypeSwitch application dependent

Input Control Voltage65 to 145 Vac 50/60 hZ

Voltage Measurements of UtilitySource 1 VAB Source 2 VAB
Source 1 VAC Source 2 VBC
Source 1 VCA Source 2 VCA

Voltage Measurement Range0 to 790 VAC rms (50/60 Hz)

Voltage Measurement Accuracy+/-2% of nominal input voltage

Frequency Measurements OfSource 1 and Source 2

Frequency Measurement Range40 Hz to 70 Hz

Frequency Measurement Accuracy+/- 0.1 Hz

Undervoltage Dropout50% to 90% of nominal voltage

Undervoltage Pickup(Dropout +2%) to 99% of the nominal system voltage

Underfrequency Dropout Range90 to 97% of the nominal system frequency

Underfrequency Pickup Range(Dropout +1 Hz) to 99% of the nominal system frequency

Overfrequency Dropout Range103 to 110% of the nominal system frequency

Overfrequency Pickup Range101% to (dropout - 1 Hz) of the nominal system frequency

Operating Temperature Range-20 to 70 degree C (-4 to +158 degree F)

Storage Temperature Range-30 to 85 degree C (-22 to +185 degree F)

Operating Humidity0 to 95% relative humidity (noncondensing)

Operating EnvironmentResistant to ammonia, methane, nitrogen,hydrogen and hydrocarbons

Generator Start Relay5A, 1/6 hp @ 250 Vac Vac 5A @ 30 Vdc with a 150W maximum load

K1, K2 Relays
10A, 1-3 hp @ 250 Vac

10A@30 Vdc

Applicable TestingUL-recognized component
Meets intent of UL 991 & UL 1008
Meets IEC 1000-4-2, 1000-4-3, 1000-4-4

Applicable Testing Continued1000-4-5, 1000-4-6, 1000-4-11
CISPR 11, Class A
FCC Part 15, Class A
CSS 22.2-178

Enclosure CompatibilityNEMA 1, NEMA 3R and NEMA 12
UV-resistant ATC-300+ faceplate

CONTACT US

REQUEST A QUOTE

Complete this form to get a quote on the equipment you are interested in.

    This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

    What You Get: A phone call from a rep or agent. A cost estimate for your machine or the project. An in-person consultation if necessary.

    *If you wish to be removed from receiving future communications, you can opt-out by texting STOP, QUIT, END, REVOKE, OPT-OUT, CANCEL, or UNSUBSCRIBE. Message and data rates may apply based on your mobile carrier’s plan. By opting into SMS communications from Blanchard Machinery, you agree to receive recurring text messages regarding account updates, order notifications, delivery notifications, and general support.