G3512 750kW Gas Generator Set

Gas Standby Rating750 ekW @ 0.8pf

Fuel TypeNatural Gas, Hydrogen Blend (up to 5%)

Emissions/Fuel StrategyU.S. EPA Certified for Non-Emergency Stationary Genset

RPM1800 rpm

Frequency60 Hz

Displacement3173in³

Engine ModelG3512

Displacement3173in³

AspirationTA

Bore6.7in

Stroke7.5in

Governor TypeADEM A4

Length205.7in

Width90in

Height99.4in

Weight27500lb

Standard

Dual air cleaners, 1 per side, with service indicator

Two-element single-stage air cleaner with enclosure and service indicator

Optional

Mounting brackets and piping

Air cleaner with precleaner

Standard

Cat ECS 100

Optional

Remote annunciator

Local alarm module

Local PC monitoring

Engine failure relay

Remote PC monitoring

Standard

Engine driven pumps for jacket water and separate circuit aftercooler

Jacket water and SCAC engine-driven pumps

Jacket water and SCAC thermostats

LH or RG connections when radiator is not selected

Package mounted radiator

Optional

Coolant level drain line with valves, fan with guard

Remote radiator for JW and SCAC circuits, level switch included but not wired

Inlet/Outlet connections

Standard

NOx sensor based air-fuel-ratio control

0.5 to 5 psi engine fuel inlet pressure

Pipeline Natural Gas: 800-1000 BTU/scf and 70-100 Methane Number

Gas Train: NFPA37 and CSA B149.3

Standard

Individual exhaust port and turbocharger outlet wired to integrated temperature sensing module (ITSM) with GCEM providing alarms and shutdowns

Dry exhaust manifolds, insulated and shielded

Cat-flanged face outlet on turbocharger

Optional

305 mm (12in.) elbow

18, 25 dBA Attenuation

Flexible fittings

305 mm (12 in.) muffler

305mm (12 in) spark arresting muffler

305 mm (12 in.) flange

Standard

Fuel system is sized for 31.5 to 47.2 MJ/NM3 dry pipeline natural gas with pressure of 10.2 to 34.5KPa to the engine fuel control valve

Throttle plate, 24V DC actuator, controlled by GECM

Engine-installed electronic control valve

Gas pressure regulator

24V DC energized-to-run (ETR) gas shutoff valve

Optional

3, 0-100 kPag, 4-20mA gas train pressure sensors

Standard

Crankshaft vibration damper and guard

Operation and maintenance manuals

Parts book

Paint- Caterpillar Yellow except rails and radiators gloss black

RH Service

Optional

Special paint order

US AID emblem

Tool set

Digital diagnostic tool

Standard

Gear type lube oil pump

Cartridge style oil filter

Standard

Anti-condensation space heater

Winding temperature detectors

NEMA Class H insulation

SR5

Permanent Magnet Excitiation

Caterpillar's Digital Voltage Regulator (CDVR) including reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, and a min/max exciter

Optional

Cable access box

Generator air filter

European bus bars

Low voltage extension box

Bearing temperature detectors

Standard

ADEM A4

Standard

Individual Cylinder Detonation Sensitive Timing (DST)

Electronic Ignition System (controlled by ADEM A4)

Standard

ADEM A4 speed governor with 4 to 20ma (0V to 5V) speed input

Standard

24V DC starting motors

Batteries with rack and cables

Electric Starter

Optional

20A, 24VDC battery charger

Battery with cables and rack

Jacket water heater

45A, 24V charging alternator (requires engine driven pumps)

Optional

S LSI, G LSIG, P LSIG-P, 4th Digit Type

Right, left, rear mounted

1200A, 3 Pole, UL-100% Rated P-Frame Circuit Breakers

1600A, 2000A 3 Pole, UL-100% Rated R-Frame Circuit Breakers

2000A 3 Pole, UL-100% Rated Masterpact Circuit Breakers

100% rated, 3-pole (UL/CSA/IEC) 5th Digit Rating

3-pole (IEC 947-2 rated)

Frame mounting

Optional

60 Hz: USA

Coming Soon